BR1500G-GR
Run time for load
Min-max: 87-865 W
W 3m 39s
Max. Capacity Used
100%
Output power capacity
865 Watts / 1.5kVA
Output Connections
(3) Schuko CEE 7 (Surge Protection)
(3) Schuko CEE 7 (Battery Backup)
Nominal Input Voltage
230V
Cord Length
1.5meters
APC Back-UPS Pro, 1500VA/865W, Tower, 230V, 6x CEE 7/7 Schuko outlets, Sine Wave, AVR, LCD, User Replaceable Battery
High Performance Computer and Electronics UPS for Premium Power Protection
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Audible alarms
Audible alarms alert you to changes in operating environment and battery conditions. Some alarms are software configurable and most can also be suppressed or delayed to eliminate nuisance alarms.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
- Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
- Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Cold-start capable
PowerShield can be turned on with a new charged battery, even if utility power is not available.
- Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Extendable Run Time
Meet long run-time needs.
- Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD display
Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
- Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
- Safety-agency approved
The UPS is UL1778 Listed
- Serial connectivity
Provides management of the UPS via a serial port.
- Telephone dataline surge protection
Provides protection of connected equipment from power surges traveling on telephone lines.
- Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Manageability
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Marketing features
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Cold-start capable
Provides temporary battery power when the utility power is out.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Nu sunt comentarii despre acest produs