Ubiquiti UniFi Access Door Hub (UA-Hub-Door)


 

 

Pretul afisat contine TVA (19%).

1.287,90 lei

Compara
Ubiquiti UniFi Access Door Hub (UA-Hub-Door)
A single-door mechanism that provides complete entry and exit control via connected Access Readers.

(2) Lock terminals (12V and Dry)

(2) AUX terminals for an external siren and automatic door opener

(4) Additional inputs (sensors and buttons)

Connect and power using PoE++

Connect to two UniFi Access readers and two UniFi Protect camera or UniFi Protect Chime

SKU: UA-Hub-Door Categorii: , ,
Mechanical
Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3″)
Weight 363 g (12.8 oz)
Enclosure material Polycarbonate
Mounting material Polycarbonate
Hardware
Networking interface (5) 10/100/1000 Base-T
Power method PoE++
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Max. power consumption Without PoE output: 30W
With PoE output: 50W
PoE input 50V DC, 1A
PoE output PoE passthrough, (4) PoE, 50V DC, total 20W
LEDs White/blue (Learn more)
Button (1) Factory-reset
Digital input Request to exit/request to enter/remote release/door position sensor
Dry output relay Lock: 30V DC, 1A
Aux: 30V DC, 1A
Powered output relay Lock: 12V DC, 1A
Aux: 12V DC, 0.33A
12V DC, 0.33A
Operating environment Indoor use only
Ambient operating temperature 0 to 40° C (32 to 104° F)
Ambient operating humidity 5 to 95% noncondensing
UL 294 level Destructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statement Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: 1
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level UA-Hub-Door002, V01
Wiring Information
Wiring gauge requirements (AWG)
Total length to device Output load current at 12V DC
100mA 250mA 500mA 1A       
6.1 m (20 ft) 22 22 22 18
15.2 m (50 ft) 22 22 22 18
30.5 m (100 ft) 22 22 18 18

UACC-Cable-DoorLockRelay (18 AWG) is recommended.

PoE cabling requirements The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm 2 ) for horizontal or riser cable.